矿用交联高压电缆

矿用交联高压电缆

产品介绍:MTJV MYJV22 MYJV32 矿用交联高压电力电缆(3.6/6 6/10 8.7/10 21/35 26/35kv)

产品详细

  6kV~35kV 中低压铜芯及铝芯交联聚乙烯绝缘电力电缆(YJV电缆,YJV22电缆,YJLV电缆,YJLV22电缆)XLPE Insulated Power Cable
  高压电力电缆 交联聚乙烯绝缘电力电缆是采用化学方法或物理方法,使聚乙烯分子由线型分子结构转变为三维网状结构,由热塑性的聚乙烯变成热固性的交联聚乙烯,从而提高了聚乙烯的耐老化性能、机械性能和耐环境能力,并保持了优良的电气性能。
  交联聚乙烯绝缘电力电缆导体的允许长期***高温为90摄氏度,较低绝缘电缆、聚氯乙烯绝缘电缆和聚乙烯绝缘电缆高,且具有重量轻、结构简单、使用方便、耐化学腐蚀和敷设不受落差限制等优点。
  26/35KV电力电缆,18/30KV交联电缆,12/20KVYJV电缆,8.7/15KVYJV22电缆线,6/10KV铝芯交联电缆线,3.6/6KVYJLV单芯电缆
  中低压交联电缆产品标准 Standard
  本产品按GB12706《额定电压35V及以下铜芯、铝芯塑料绝缘电力电缆》标准生产,同时还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。
  The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request.
  适用范围 Applications
  本产品适用于工频额定电压3.6/6kv~26/35kv输配电线路作配送电能子用。
  The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
  使用特性 Operating characteristics
  · 工频额定电压U0/U为3.6/6kv~26/35kv。
  Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
  · 电缆导体的***高允许工作温度:90℃。
  Max.admissible operating temperature of the conductor:90℃.
  · 短路时(***长时间不超过5s)电缆导体的***高温度不超过2500C。
  Max. short-circurt temperature of conductor shall not exceed 2500C.
  (5s maximum duration) · 电缆敷设时环境温度应不低于00C。
  The ambient temperature under installation should not below 00C.
  · 电缆弯曲半径:三芯电缆不小于电缆外径15倍;单芯电缆不小于电缆外径20倍。
  The bending radius of a single-core cable should not less than 20 times of the cable diameter.
  The bending radius of a single-core cable should not less than 15 times of the cable diameter.
  电缆额定电压的选择 Voltage designation
  · 电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。
  U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压;
  U-电缆设计用的导体间的额定工频电压;
  Um-设备可承受的“***高系统电压”的***大值。
  The rated voltage of the cable for a given applixation shall be suitable for the operating conditions
  in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv
  Where:
  U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed;
  U - The rated power-frequency voltage between conductos, for which the cable designed;
  Um- The maximum value of the“highest system voltage”for which the equipment may beused.

三相系统用电缆的U0值推荐如下表:
The values of U0 recommened for cable to be used in three-phase systems are listed below:

 

U kvU m kvU 0 * kvA 和 B 类系统 System categories A and BC 类系统 Systems categories C67.23.66101268.71517.58.71220241218303618-3540.52126
A类系统──该类系统任何一相导体与地和接地导体接触时,能在1min内与系统分离
B类系统──该类系统仅包括单相接地故障短时运行的条件,接地故障时间应不超过1h, 但在任何情况下,***长不超过8h每年接地故障总持续时间不超过125h;
C类系统──不属于A类、B类的系统。
System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min.
System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h.
System categeory C──This category comprises all systems which do not fall into A and B
电缆的型号Type of cable
型号 Type名称 Designation适用范围 ApplicationYJV铜芯交联聚乙烯绝缘氯乙烯护套电力电缆 Copper conductor,XLPE insulated and PVC sheathed power cable室内、隧道及电缆沟等场所,不能承受机械外力。单芯电缆不允许敷设在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissibleYJLY铝芯交联聚乙烯绝缘乙烯护套电力电缆 Aluminium conductor, XLPE insulated and PVC sheathed power cableYJY铜芯交联聚乙烯绝缘氯乙烯护套电力电缆 Copper conductor ,XLPE insulated and PEsheathed power cableYJLY铝芯交联聚乙烯绝缘氯乙烯护套电力电缆 Alumimium conductor ,XLPE

产品介绍:高压交联电缆产品具有传输容量大,工作温度,不受落差的限制,安装敷设方便等特点,广泛应用于工矿企业和城市电网中。高压交联电缆主要用于电力、建筑、工矿、冶金、交通等部门的动力、照明输配电系统,由于聚乙烯是电绝缘性能***好的塑料,加上经过高分子交联后成为热固性材料,因此其电性能好,机械性能和耐热性好。近二十年来,已成为中国中、高压电缆的主导品种,产品适用于6——35KV的各个电压级中它可分为:YJV-交联聚乙稀绝缘聚氯乙烯护套电力电缆,YJV22-交联聚乙烯绝缘钢带铠装高压电缆,YJLV-交联聚乙烯绝缘铝芯钢带铠装高压电缆。
执行标准:GB/T12706-2002
使用特性
· 工频额定电压U0/U为6kv/10kv~26/35kv。
· 电缆导体的***高允许工作温度:90℃。
· 短路时(***长时间不超过5s)电缆导体的***高温度不超过2500C。
· 电缆敷设时环境温度应不低于00C。
· 电缆弯曲半径:三芯电缆不小于电缆外径15倍;单芯电缆不小于电缆外径20倍。
电缆额定电压的选择
· 电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。
U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压;
U-电缆设计用的导体间的额定工频电压;
Um-设备可承受的“***高系统电压”的***大值。

产品参数:

导体标称截面 绝缘
厚度
护套
厚度
电缆近似外径 电缆近似重量 20℃
导体
电缆载流量 短路电流
直流
电阻
在空
气中
直埋土壤中 导 体 屏蔽层
铜带 铜丝
mm 2 mm mm mm kg/km Ω/km A A KA KA KA
3×25 3.4 2.4 48 3190 0.727 120 125 3.69 2.958 -
3×35 3.4 2.5 50 3731 0.524 140 155 5.15 2.958 -
3×50 3.4 2.6 53 4396 0.387 165 180 7.31 2.958 -
3×70 3.4 2.7 57 5198 0.268 210 220 10.2 2.958 -
3×95 3.4 2.9 62 6350 0.193 355 265 13.8 2.958 -
3×120 3.4 3 65 7257 0.153 290 300 17.4 2.958 -
3×150 3.4 3.1 69 8383 0.124 330 340 21.7 2.958 -
3×185 3.4 3.2 72 9741 0.0991 375 380 26.7 2.958 -
3×240 3.4 3.3 78 11854 0.0754 435 435 34.6 3.301 -
3×300 3.4 3.4 84 14861 0.0601 495 485 43.1 3.301 -

 